  "parameters": [
    {
      "aspect": {
        "name": "frequency",
        "ml_name": "as_frequency",
        "id": "AS12"
      },
      "measurand": null,
      "measurandtaxon": "MeasureRatioAmplitudeModulation",
      "id": 219,
      "name": "Frequency",
      "quantitykind": "frequency",
      "definition": "Carrier Frequency",
      "optional": false
    },
    {
      "aspect": null,
      "measurand": null,
      "measurandtaxon": "MeasureRatioAmplitudeModulation",
      "id": 220,
      "name": "Depth",
      "quantitykind": "ratio",
      "definition": "Amplitude Modulation Depth",
      "optional": false
    },
    {
      "aspect": {
        "name": "power",
        "ml_name": "as_power",
        "id": "AS19"
      },
      "measurand": null,
      "measurandtaxon": "MeasureRatioAmplitudeModulation",
      "id": 221,
      "name": "Power",
      "quantitykind": "power",
      "definition": "Carrier Power Level",
      "optional": true
    },
    {
      "aspect": {
        "name": "frequency",
        "ml_name": "as_frequency",
        "id": "AS12"
      },
      "measurand": null,
      "measurandtaxon": "MeasureRatioAmplitudeModulation",
      "id": 222,
      "name": "Rate",
      "quantitykind": "frequency",
      "definition": "Modulation Rate Frequency",
      "optional": true
    },
    {
      "aspect": null,
      "measurand": null,
      "measurandtaxon": "MeasureRatioAmplitudeModulation",
      "id": 223,
      "name": "Detector",
      "quantitykind": null,
      "definition": "{+Peak, -Peak, Average, PeakToPeak, RMS}",
      "optional": true
    },
    {
      "aspect": {
        "name": "frequency",
        "ml_name": "as_frequency",
        "id": "AS12"
      },
      "measurand": null,
      "measurandtaxon": "MeasureRatioAmplitudeModulation",
      "id": 224,
      "name": "HighPassFilter",
      "quantitykind": "frequency",
      "definition": "High Pass Filter Frequency",
      "optional": true
    },
    {
      "aspect": {
        "name": "frequency",
        "ml_name": "as_frequency",
        "id": "AS12"
      },
      "measurand": null,
      "measurandtaxon": "MeasureRatioAmplitudeModulation",
      "id": 225,
      "name": "LowPassFilter",
      "quantitykind": "frequency",
      "definition": "Low Pass Filter Frequency",
      "optional": true
    },
    {
      "aspect": null,
      "measurand": null,
      "measurandtaxon": "MeasureRatioAmplitudeModulation",
      "id": 226,
      "name": "BandPassFilter",
      "quantitykind": null,
      "definition": "Band Pass Filter Frequency or CCIT",
      "optional": true
    }
  ],
  "external_references": [],
  "aspect": null,
  "discipline": {
    "label": "Electrical"
  },
  "id": "MeasureRatioAmplitudeModulation",
  "name": "Measure.Ratio.AmplitudeModulation",
  "definition": "The process of measuring the Percent of Modulation of an Amplitude Modulation (AM) Signal.",
  "deprecated": false,
  "replacement": "",
  "quantitykind": "ratio",
  "processtype": "Measure",
  "qualifier": "",
  "result": "Depth",
  "result_quantity": "ratio"
}