  "parameters": [
    {
      "aspect": null,
      "measurand": null,
      "measurandtaxon": "SourceRatioAccelerationDeltaFrequency",
      "id": 491,
      "name": "OutputQuantity",
      "quantitykind": null,
      "definition": "{charge, resistance, capacitance, voltage}",
      "optional": false
    },
    {
      "aspect": null,
      "measurand": null,
      "measurandtaxon": "SourceRatioAccelerationDeltaFrequency",
      "id": 492,
      "name": "Sensitivity",
      "quantitykind": null,
      "definition": "Output quantity divided by the input acceleration",
      "optional": false
    },
    {
      "aspect": {
        "name": "frequency",
        "ml_name": "as_frequency",
        "id": "AS12"
      },
      "measurand": null,
      "measurandtaxon": "SourceRatioAccelerationDeltaFrequency",
      "id": 493,
      "name": "FrequencyRef",
      "quantitykind": "frequency",
      "definition": "Reference Frequency",
      "optional": false
    },
    {
      "aspect": {
        "name": "frequency",
        "ml_name": "as_frequency",
        "id": "AS12"
      },
      "measurand": null,
      "measurandtaxon": "SourceRatioAccelerationDeltaFrequency",
      "id": 494,
      "name": "Frequency",
      "quantitykind": "frequency",
      "definition": "Test Frequency",
      "optional": false
    },
    {
      "aspect": null,
      "measurand": null,
      "measurandtaxon": "SourceRatioAccelerationDeltaFrequency",
      "id": 495,
      "name": "Axis",
      "quantitykind": null,
      "definition": "{X,Y, Z}",
      "optional": true
    },
    {
      "aspect": {
        "name": "acceleration",
        "ml_name": "as_acceleration",
        "id": "AS39"
      },
      "measurand": null,
      "measurandtaxon": "SourceRatioAccelerationDeltaFrequency",
      "id": 496,
      "name": "Acceleration",
      "quantitykind": "acceleration",
      "definition": "Acceleration (m/s\u00b2)",
      "optional": true
    },
    {
      "aspect": {
        "name": "electric-potential",
        "ml_name": "as_electric_potential_difference",
        "id": "AS22"
      },
      "measurand": null,
      "measurandtaxon": "SourceRatioAccelerationDeltaFrequency",
      "id": 497,
      "name": "ExcitationVoltage",
      "quantitykind": "voltage",
      "definition": "Excitation Voltage",
      "optional": true
    }
  ],
  "external_references": [],
  "aspect": null,
  "discipline": {
    "label": "Vibration"
  },
  "id": "SourceRatioAccelerationDeltaFrequency",
  "name": "Source.Ratio.Acceleration.Delta.Frequency",
  "definition": "UUT is placed in a device, normally a shaker, which then moves in a single axis direction at a known acceleration at the reference frequency. Then the frequency is changed to the Test Frequency and difference in sensitivity is expressed as a ratio (Test Frequency / Ref Frequency).",
  "deprecated": false,
  "replacement": "",
  "quantitykind": "ratio",
  "processtype": "Source",
  "qualifier": "",
  "result": "Ratio",
  "result_quantity": "ratio"
}